15.1 Static electricity and surge protection using SM712/WP61150B
Ethernet usually uses line-to-line and line-to-ground static electricity and surge protection technology, with a maximum signal rate of 10Gbit/s. This speed requires consideration of the capacitance of the suppressor. As shown in the figure below, WPE3V3D3UW is used to protect secondary high-speed lines. Using the semiconductor discharge tube LANTSPD-C8 in conjunction with RC, it can effectively provide common mode surge protection for first-level high-speed lines.
Comply with standards: ESD IEC 61000-4-2 Level 4 Surge IEC 61000-4-5 Level 4 (communication combination wave)
| P/N |
Package |
CJ |
ESD IEC61000-4-2 |
Surge IEC61000-4-5 |
Applicable version |
|---|---|---|---|---|---|
| WP61150MB | SMB | 80pF | 30KV | 6KV(10/700μ) | / |
| SM712 | SOT-23 | 50pF | 30KV | 12A(8/20μs) | / |